Insert electromagnetic flowmeter
Specification Connect plug-in Material quality plain type DN100~DN3000 Ball valve type DN100~DN3000 Accuracy ±2.5%R Range ratio 1:20 Flow rate range 0.5~10m/s Medium temperature -20℃~+60℃ / -20℃~+160℃ Output 4~20mA / RS485 Introduction Intelligent plug-in electromagnetic flowmeter, suitable for liquid wastewater, sewage, tap water, paper slurry, integrated ball valve … -
Split electromagnetic flowmeter
Specification Connect split type Material quality PTFE lining DN10~DN600 Rubber lining DN40~DN2000 Accuracy ±0.5%R Range ratio 1:20 Flow rate range 0.5~10m/s Medium temperature -20℃~+60℃ / -20℃~+160℃ Output 4~20mA / RS485 Introduction Split-type electromagnetic flowmeter, to prevent external noise intrusion, signal cables usually use double core shielded wires, … -
Vortex flowmeter
Specification Connect general type Material quality flange installation DN25~DN300 Accuracy ±0.5%R Range ratio 1:10 /1:15 Flow rate range 5~50m/s (gas) 0.5~7m/s (liquid) Medium temperature -40℃~+70℃ / -40℃~+350℃ Output 4~20mA / RS485 Introduction Vortex flowmeter work on the principle of generated vortex and relation between vortex and flow by … -
Temperature/pressure compensated eddy current flowmeter
Specification Connect temperature pressure compensation type Material quality flange installation DN25~DN300 Accuracy ±0.5%R Range ratio 1:10 /1:15 Flow rate range 5~50m/s (gas) 0.5~7m/s (liquid) Medium temperature -40℃~+70℃ / -40℃~+350℃ Output 4~20mA / RS485 Introduction Temperature/pressure compensated eddy current flowmeter, with good vibration resistance, no zero drift output, … -
Turbine Flowmeter
Specification Measurement medium Water, refined oil, light crude oil, organic liquid, inorganic liquid Material quality DN4~DN300 Accuracy ± 1% R, ± 0.5% R, ± 0.2% R (customized) Range ratio 1:10;1:15;1:20 material quality 304 / 316 stainless steel Medium temperature -20℃~+120℃ Output Pulse signal, 4-20mA signal Introduction Intelligent turbine flowmeter, installed … -
Wall mounted temperature and humidity transmitter
Specification Relative humidity 0~99.9% RH Accuracy ± 3% RH Resolution 0.1% RH Temperature 0~50℃ / -20~80℃ / -40~60℃ Accuracy (25℃)±0.3℃ Resolution 0.1 ℃ Long term stability <0.1 ℃/year Introduction Wall mounted voltage 4-20mA/RS485 temperature and humidity transmitter, suitable for temperature measurement in HVAC indoor and outdoor environments. This temperature and … -
LED display wall mounted temperature and humidity transmitter
Specification Relative humidity 0~99.9% RH Accuracy ± 3% RH Resolution 0.1% RH Temperature 0~50℃ / -20~80℃ / -40~60℃ Accuracy (25℃)±0.3℃ Resolution 0.1 ℃ Long term stability <0.1 ℃/year Introduction Wall mounted voltage 4-20mA/RS485 temperature and humidity transmitter, suitable for temperature measurement in HVAC indoor and outdoor environments. This temperature and … -
Pipeline temperature and humidity transmitter
Specification Relative humidity 0~99.9% RH Accuracy ± 3% RH Resolution 0.1% RH Temperature 0~50℃ / -20~80℃ / -40~60℃ Accuracy (25℃)±0.3℃ Resolution 0.1 ℃ Long term stability <0.04 ℃/year Introduction The pipeline type temperature and humidity transmitter is very suitable for measuring temperature and humidity in various places suitable for pipeline … -
High temperature and humidity sensors
Specification Relative humidity 0~99.9% RH Accuracy ± 3% RH Resolution 0.1% RH Temperature 0~50℃/-20~80℃/-40~60℃/0~120℃ Accuracy (25℃)±0.3℃ Resolution 0.1 ℃ Long term stability <0.5 %RH/Y Introduction High temperature temperature and humidity sensor Industrial pipeline stainless steel baking drying flue gas HVAC pharmaceutical temperature and humidity meter size -
Voltage transmitter
Specification Accuracy 0.5% Linearity 0.1% Power DC12-24V / AC 110-220V Measure 0V~1200V Way Wiring type Output 4~20mA or other Overload capacity 2x nominal input sustainable Introduction A device that converts the measured AC voltage, DC voltage, and pulse voltage into a linear proportional output of DC voltage or DC current, …